Non-contact voltage probe, Non-contact CAN sensors
NON-CONTACT CAN SENSOR SP7001, SP7002
• Innovative non-contact CAN/CAN FD sensor that improves testing productivity
• Capture signals without affecting CAN bus or ECUs
• No need to alter vehicle cables
• High-sensitivity mode for hard to detect signals
NON-CONTACT AC VOLTAGE PROBE SP3000
• Capture voltage signals from outside the wire cover
• Supports φ1mm to 2.5mm covered wires
• 10Hz to 100kHz frequency bandwidth
• 5Vrms 14Vp-p rated measurement voltage
Wide-band Current Probes, DC to 120 MHz
CURRENT PROBE CT6710
• High-sensitivity for observing micro currents down to 0.5A • Ideal for developing switching power supplies • High S/N ratio
• DC to 50 MHz (−3dB), ±3.0% accuracy
• Maximum 30 A rms, 3 ranges
• ±50 A peak (non-continuous)
CURRENT PROBE CT6711
• High-sensitivity for observing micro currents down to 0.5A • Ideal for developing switching power supplies • High S/N ratio, high frequency
• DC to 120 MHz (−3dB), ±3.0% accuracy
• Maximum 30 A rms, 3 ranges
• ±50 A peak (non-continuous)
CURRENT PROBE CT6700
• High-sensitivity for observing micro currents down to 1 mA • Ideal for developing switching power supplies, inverts and motor controllers • High S/N ratio
• DC to 50 MHz (−3dB), ±3.0% accuracy
• Maximum 5 A rms
• ±7.5 A peak (non-continuous)
CURRENT PROBE CT6701
• High-sensitivity for observing micro currents down to 1 mA • Ideal for developing switching power supplies, inverts and motor controllers • High S/N ratio, high frequency
• DC to 120 MHz (−3dB), ±3.0% accuracy
• Maximum 5 A rms
• ±7.5 A peak (non-continuous)
CLAMP ON PROBE 3273-50
• Observe currents down to 10 mA • High S/N ratio • Ideal for capturing transient current signals from switching power supplies, inverters, and motor controllers
• DC to 50MHz (−3dB), ±1.0% accuracy
• Maximum 30 A rms
• ±50 A peak (non-continuous)
CLAMP ON PROBE 3276
• Observe currents down to 10 mA • Ideal for capturing transient current signals from switching power supplies, inverters, and motor controllers • High S/N ratio, high frequency
• DC to 100 MHz (−3dB), ±1.0% accuracy
• Maximum 30 A rms
• ±50 A peak (non-continuous)
CLAMP ON PROBE 3275
• High S/N ratio • Directly connect to high impedance BNC input of oscilloscope or recorder • Ideal for capturing transient current signals from switching power supplies, inverters, and motor controllers
• DC to 2MHz (−3dB), ±1.0% accuracy
• Maximum 500 A rms
• ±700 A peak (non-continuous)
CLAMP ON PROBE 3274
• High S/N ratio • Directly connect to high impedance BNC input of oscilloscope or recorder • Ideal for capturing transient current signals from switching power supplies, inverters, and motor controllers
• DC to 10MHz (−3dB), ±1.0% accuracy
• Maximum 150 A rms
• ±300 A peak (non-continuous)
High-precision Current Sensors, DC to 4 MHz
AC/DC CURRENT SENSOR CT6877
• High-accuracy sensor using the zero flux method and flux gate detection • High-current, high-speed EV, HEV inverter testing • Measure battery charge/discharge and secondary side of inverter motors
• DC to 1 MHz, ±0.04% accuracy
• Rated 2000A AC/DC
AC/DC CURRENT SENSOR CT6875
• High-accuracy sensor using the zero flux method and flux gate detection • Test inverter efficiency, inverter output power, reactor or transformer loss • Ideal for long-term DC measurements
• DC to 2MHz, ±0.04% accuracy
• Rated 500A AC/DC
AC/DC CURRENT SENSOR CT6876
• High-accuracy sensor using the zero flux method and flux gate detection • Test inverter efficiency, inverter output power, reactor or transformer loss • Ideal for long-term DC measurements
• DC to 1.5MHz, ±0.04% accuracy
• Rated 1000A AC/DC
AC/DC CURRENT SENSOR CT6904
• High-accuracy sensor using the zero flux method and flux gate detection • Capture current signals from switching power supplies, inverters % power conditioners
• DC to 4 MHz, ±0.02% accuracy
• Rated 500A AC/DC (up to 800 A special order available)
AC/DC CURRENT PROBE CT6846-05
• High accuracy clamp sensor for evaluating against WLTC and automotive new fuel economy standards • EV/HEV battery charge and discharge efficiency testing • Inverter and power conditioner conversion efficiency evaluations
• DC to 20kHz, ±0.3% accuracy
• Rated 1000A AC/DC
AC/DC CURRENT BOX PW9100
• Test power conversion efficiency of motors, inverters, HEV, and renewable energy equipment
• Max. 50 A AC direct input to the PW6001/PW3390
• Wide DC to 3.5MHz, ±0.02% accuracy
• PW9100-03: 3ch
• PW9100-04: 4ch
AC/DC CURRENT PROBE CT6845-05
• Wideband and high-precision current probe for power efficiency testing • Evaluate EV/HEV battery charge and discharge efficiency • Measure inverter and power conditioner conversion
• DC to 100kHz, ±0.3% accuracy
• Rated 500 A AC/DC
AC/DC CURRENT PROBE CT6844-05
• Wideband and high-precision current probe for power efficiency testing • Evaluate EV/HEV battery charge and discharge efficiency • Measure inverter and power conditioner conversion efficiency
• DC to 200kHz, ±0.3% accuracy
• Rated 500A AC/DC
AC/DC CURRENT SENSOR CT6862-05
• Wideband, high-precision pass-through sensor with wide temperature range • Evaluate solar power generation and fuel cells to measure battery charge and discharge and the secondary side of inverters
• DC to 1MHz, ±0.05% accuracy
• Rated 50A AC/DC
AC/DC CURRENT SENSOR CT6863-05
• Wideband, high-precision pass-through sensor with wide temperature range • Evaluate solar power generation and fuel cells to measure battery charge and discharge and the secondary side of inverters
• DC to 500kHz, ±0.05% accuracy
• Rated 200A AC/DC
AC/DC CURRENT PROBE CT6841-05
• Wideband, high-precision current probe for power efficiency testing • Evaluate EV/HEV battery charge and discharge efficiency • Measure inverter and power conditioner conversion efficiency
• DC to 1MHz, ±0.3% accuracy
• Rated 20A AC/DC
AC/DC CURRENT PROBE CT6843-05
• Wideband, high-precision current clamp sensor for power efficiency testing • Measuring the charge and discharge efficiency of EV/HEV batteries • Evaluate inverter and power conditioner efficiency
• DC to 500kHz, ±0.3% accuracy
• Rated 200A AC/DC
AC/DC Current Sensors, DC to 20 kHz
DISPLAY UNIT CM7291 (Bluetooth®)
• Combine with CT7000 series AC/DC current sensors or output to data acquisition equipment
• Bluetooth(R) wireless technology
• Pair with CT7000 series
• DCA, ACA, (DC+AC)A, frequency
• WAVE, RMS, PEAK, Hz output
AC/DC CURRENT SENSOR CT7631
• Observe instantaneous waveforms in laboratories and other temperature-controlled environments • Ideal for site inspections by pairing with CM7290/CM7291 Display Unit • Output 4 types of data to loggers or other DAQ via Display Unit
• DC to 10 kHz, ±1.0% accuracy
• Rated 100 A AC/DC
AC/DC AUTO-ZERO CURRENT SENSOR CT7742
• Make measurements over extended periods of time without the need to perform zero-adjustment • Ideal for measuring in locations with temperature variations
• DC to 5 kHz, ±1.5% accuracy
• Rated 2000A AC/DC
AC/DC AUTO-ZERO CURRENT SENSOR CT7736
• Make measurements over extended periods of time without the need to perform zero-adjustment • Ideal for measuring in locations with temperature variations
• DC to 5 kHz, ±2.0% accuracy
• Rated 600A AC/DC
AC/DC AUTO-ZERO CURRENT SENSOR CT7731
• Make measurements over extended periods of time without the need to perform zero-adjustment • Ideal for measuring in locations with temperature variations
• DC to 5 kHz, ±1.0% accuracy
• Rated 100A AC/DC
AC/DC CURRENT SENSOR CT7642
• Observe instantaneous waveforms in laboratories and other temperature-controlled environments • Ideal for site inspections by pairing with CM7290/CM7291 Display Unit • Output 4 types of data to loggers or other DAQ
• DC to 10kHz, ±1.5% accuracy
• Rated 2000 A AC/DC
AC/DC CURRENT SENSOR CT7636
• Observe instantaneous waveforms in laboratories and other temperature-controlled environments • Ideal for site inspections by pairing with CM7290/CM7291 Display Unit • Output 4 types of data to loggers or other DAQ
• DC to 10kHz, ±2.0% accuracy
• Rated 600 A AC/DC
DISPLAY UNIT CM7290
• Combine with CT7000 series AC/DC current sensors or output to data acquisition equipment
• Pair with CT7000 series
• DCA, ACA, (DC+AC)A, frequency
• WAVE, RMS, PEAK, Hz output
AC Current Sensors, up to 50 kHz
CLAMP ON SENSOR 9272-05
• Measuring AC current with low frequencies such as inverter control devices • Wide bandwidth ideal for harmonic analysis, FFT analysis and waveform monitoring
• 1Hz to 100kHz, ±0.3% accuracy
• Rated 20A/200A AC/DC
AC FLEXIBLE CURRENT SENSOR CT7040 series
• Flexible Rogowski sensor easy routes through confined locations and around thick cables • Tapered tip designed to feed readily through tangled wires
• 10 Hz to 50 kHz, ±1.5% accuracy
• 600A or 6000A AC rated
AC FLEXIBLE CURRENT SENSOR CT9667
• Rogowski type AC sensors in 3 different loop diameter sizes from 100 to 254 mm • Battery or AC Adapter-powered to pair with any power meter or DAQ • Thin coil easy to use in confined spaces and with complicated wiring
• 10 Hz to 20 kHz, ±2% accuracy
• Rated 5000 A/ 500 A AC
CLAMP ON LEAK SENSOR 9675
• Leak current sensor with voltage output • Pair with Hioki power logger or 2-channel data logger
• 40 Hz to 5 kHz, ±1.0% accuracy
• Rated 10 A AC, 100 mV/A output rate
CLAMP ON LEAK SENSOR 9657-10
• Leak current sensor with voltage output • Also measure load thanks to max. 30A continuous input
• 40 Hz to 5 kHz, ±1.0 accuracy
• Rated 10 A AC, 100 mV/A output rate
CLAMP ON SENSOR 9695-03
• High accuracy AC current sensor with voltage output • Measure inverter devices or commercial power lines • Compact design fits in to narrow spaces
• 40Hz to 5kHz, ±0.3% accuracy
• Rated 100 A AC, 1 mV/A output rate
CLAMP ON SENSOR 9695-02
• High accuracy AC current sensor with voltage output • Measure inverter devices or commercial power lines • Compact design fits in to narrow spaces
• 40Hz to 5kHz, ±0.3% accuracy
• Rated 50 A AC, 10 mV/A output rate
CLAMP ON SENSOR 9694
• High accuracy AC current sensor with voltage output • For inverter devices or commercial power lines • For measuring the secondary side of 5A CTs
• 40Hz to 5kHz, ±0.3% accuracy
• Rated 5 A AC, 10 mV/A output rate
CLAMP ON SENSOR 9669
• High accuracy AC current sensor with voltage output • For inverter devices or commercial power lines
• 40Hz to 5kHz, ±1.0% accuracy
• Rated 1000 A AC, 0.5 mV/A output rate
CLAMP ON SENSOR 9661
• High accuracy AC current sensor with voltage output • For inverter devices or commercial power lines
• 40Hz to 5kHz, ±0.3% accuracy
• Rated 500 A AC, 1 mV/A output rate
CLAMP ON SENSOR 9660
• High accuracy AC current sensor with voltage output • For inverter devices or commercial power lines • Compact design fits into narrow spaces
• 40Hz to 5kHz, ±0.3% accuracy
• Rated 100 A AC, 1 mV/A output rate
Load Current Sensors
CLAMP ON PROBE 9132-50
• General purpose wide range clamp sensor for monitoring current level • 6 ranges to meet a diverse range of applications • Capture waveforms to output to DMMs and Hioki Memory HiCorders
• 40 Hz to 1 kHz, ±3% accuracy
• 20 to 1000A AC
CLAMP ON PROBE 9018-50
• General purpose wide range clamp sensor for monitoring current level • 6 ranges and excellent phase characteristics to meet a diverse range of applications • Record and analyze waveforms and harmonic signals
• 40 Hz to 3 kHz, ±1.5% accuracy
• 10 to 500A AC
• Max. 650 A rms continuous input
CLAMP ON PROBE 9010-50
• General purpose wide range clamp sensor for monitoring current level • 6 ranges to meet a diverse range of applications • Capture waveforms to output to DMMs and Hioki Memory HiCorders
• 40 Hz to 1 kHz, ±2% accuracy
• 10 to 500 A AC
• Max. 650 A rms continuous input
Power Supplies for Current Sensors
SENSOR UNIT CT9557
• Power supply for current sensors when used as standalone sensors • Output individual or single waveform from an aggregate of input waveforms • Use with high precision sensors to measure equipment such as high-capacity solar power conditioners and inverters
• 4 channels, ±0.06% DC accuracy
• Waveform, total waveform, and total RMS output
SENSOR UNIT CT9556
• Power supply for current sensors when used as standalone sensors • Use with high precision sensors to measure equipment such as high-capacity solar power conditioners and inverters
• 1 channel, ±0.2% DC accuracy
• Waveform and RMS output
SENSOR UNIT CT9555
• Power supply for current sensor when used as standalone sensor • Use with high precision sensors to measure equipment such as high-capacity solar power conditioners and inverters
• 1 channel
• Waveform output
POWER SUPPLY 3269
• Power supply for wideband current probes for output to Memory HiCorders or oscilloscopes
• 2 channels for CT6710 series or 4 channels for CT6700 and 3270 series
• ±12 V output
POWER SUPPLY 3272
• Power supply for wideband current probes for output to Memory HiCorders or oscilloscopes